| model |
G8300 |
G8500 |
G8600 |
G9800 |
G18500 |
G18800 |
|
Hardware specifications
|
| Maximum number of controllers |
16 |
32 |
32 |
32 |
32 |
32 |
| Machine architecture |
Integrated disk controller (2U 25 disks) |
Integrated disk controller (2U 36 disks) |
Integrated disk controller (2U 36 disks) |
Independent head (4U4 control) |
Independent head (4U4 control) |
Independent head (4U4 control) |
| Maximum number of controllers per chassis |
2 |
2 |
2 |
4 |
4 |
4 |
| Each CPU |
Kunpeng920 32 cores 2.6GHz |
Kunpeng920 64 cores 2.6GHz |
Kunpeng920 96 cores 2.6GHz |
Kunpeng920 128 cores 2.6GHz |
Kunpeng920 128 cores 2.6GHz |
Kunpeng920 192 cores 2.6GHz |
| Cache capacity configuration
(per controller) |
128G/controller (4*32G) |
192G/controller (12*16G)
256G/controller (16*16G |
384G/controller (12*32G)
512G/controller (16*32G) |
256G/controller (16*16G)
512G/controller (16*32G)
1024G/controller (16*64G) |
256G/controller (16*16G)
512G/controller (16*32G)
1024G/controller (16*64G) |
512G/controller (16*32G)
1024G/controller (16*64G) |
| Supported storage protocols |
FC, iSCSI, NFS, CIFS |
| Front channel port type |
8/16/32 Gbit/s FC/FC-NVMe*, 10/25/40/100GE, 25/100G NVMe over RoCE* |
| Back-end channel port type |
100G RDMA/SAS 3.0 |
| Maximum number of hot-swappable I/O modules per controller enclosure |
6 |
12 |
12 |
28 |
28 |
28 |
| Maximum number of front-end host interfaces/controller enclosure |
Number of control boxes*2*
(FC:2*4
40/100GE: 2*2
10GE (optical port): 2*4+4
10GE (electrical port): 2*4
25GE: 2*4
GE: 2*4+4
25GRoCE: 2*4) |
Number of control boxes*2*
(FC:5*4
40/100GE: 5*2
10GE/25G: 5*4
25G RoCE: 5*4
100G RoCE: 5*2) |
Number of control boxes*2*
(FC:5*4
40/100GE: 5*2
10GE/25G: 5*4
25G RoCE: 5*4
100G RoCE: 5*2) |
Number of control boxes*
(FC:20*4
40/100GE: 20*2
10GE/25G: 20*4
25G RoCE: 20*4) |
Number of control boxes*
(FC:20*4
40/100GE: 20*2
10GE/25G: 20*4
25G RoCE: 20*4) |
Number of control boxes*
(FC:20*4
40/100GE: 20*2
10GE/25G: 20*4
25G RoCE: 20*4) |
| Maximum number of disks |
1000 |
1200 |
1500 |
3200 |
Non-cross-chassis RAID: 6400
Cross-chassis RAID: 4800 |
Non-cross-chassis RAID: 9600
Cross-chassis RAID: 6400 |
| Hard Drive Type |
1.92TB/3.84TB/7.68TB palm-sized NVMe SSD, 960GB/1.92TB/3.84TB/7.68TB/15.36TB SAS SSD |
| Support SCM |
800 GB* SCM |
|
Software Specifications
|
| RAID support |
RAID10*, RAID 5, RAID 6, and RAID-TP (tolerate simultaneous failure of 3 disks) |
| Maximum number of LUN groups |
4096 |
8192 |
8192 |
16384 |
16384 |
16384 |
| Value-added software |
Smart Online Deduplication (SmartDedupe) Smart Heterogeneous Virtualization (SmartVirtualization) Smart Online Compression (SmartCompression) Smart LUN Migration (SmartMigration) Smart Thin Provisioning (SmartThin) Smart Quality of Service (SmartQoS) Snapshot (HyperSnap) Remote Replication (HyperReplication) Clone (HyperClone) Active-Active Array (HyperMetro) Continuous Data Protection (HyperCDP) Cloud Backup (CloudBackup)* Smart Data Tier (SmartTier)* Smart SCM Cache Acceleration (SmartCache)* Quota Management (SmartQuota)* Smart Multi-Tenant (SmartMulti-tenant)* |
| Storage Management Software |
Device Management (DeviceManager) Multipath Management (UltraPath) Remote Maintenance Management (eService) |
|
Electrical Specifications
|
| power supply |
SAS disk enclosure: 100V~240V AC±10%, 192V~288V DC Controller enclosure/intelligent SAS disk enclosure/intelligent NVMe disk enclosure: 200V~240V AC±10%, 100~240V ac±10%, 192V~288V DC, 260V~400V DC |
SAS disk enclosure: 100V~240V AC±10%, 192V~288V DC Controller enclosure/intelligent SAS disk enclosure/intelligent NVMe disk enclosure: 200V~240V AC±10%, 192V~288V DC, 260V~400V DC |
| Dimensions (H x W x D) |
SAS controller enclosure 86.1 mm × 447 mm × 820 mmNVMe controller enclosure 86.1 mm × 447 mm × 920 mmSAS hard disk enclosure 86.1 mm × 447 mm × 410 mmIntelligent SAS hard disk enclosure 86.1 mm × 447 mm × 520 mmNVMe hard disk enclosure 86.1 mm × 447 mm × 620 mm |
SAS controller enclosure 86.1 mm × 447 mm × 820 mmNVMe controller enclosure 86.1 mm × 447 mm × 920 mmSAS hard disk enclosure 86.1 mm × 447 mm × 410 mmIntelligent SAS hard disk enclosure 86.1 mm × 447 mm × 520 mmNVMe hard disk enclosure 86.1 mm × 447 mm × 620 mm |
| weight |
SAS controller enclosure ≤ 45kg NVMe controller enclosure ≤ 50kg SAS hard disk enclosure ≤ 20kg SAS intelligent hard disk enclosure ≤ 30kg NVMe intelligent hard disk enclosure ≤ 35kg |
SAS controller enclosure ≤ 45kg NVMe controller enclosure ≤ 50kg SAS hard disk enclosure ≤ 20kg SAS intelligent hard disk enclosure ≤ 30kg NVMe intelligent hard disk enclosure ≤ 35kg |
| Working temperature |
The ambient temperature at an altitude of -60 to +1800 m is 5°C to 35°C (cabinet)/40°C (frame). At an altitude of 1800 to 3000 m, the ambient temperature (upper limit) decreases by 1°C for every 220 m increase in altitude. |
The ambient temperature at an altitude of -60 to +1800 m is 5°C to 35°C (cabinet)/40°C (frame). At an altitude of 1800 to 3000 m, the ambient temperature (upper limit) decreases by 1°C for every 220 m increase in altitude. |
| Working environment humidity |
10%~90%RH |
10%~90%RH |
Reviews